Abstract
This paper represents a novel reference compensation current estimation method for control of shunt active power filter (APF). The method allows the reference compensation currents are determined in the a-b-c reference frame and there is no reference frame transformation requirement, so the proposed system becomes very simple. The current control is done in time domain. The compensating current flows into the power feeder in order to suppress the harmonic currents generated by nonlinear loads. A three-phase active power filter is simulated with Matlab/Simulink to demonstrate the performance of the proposed method. The results verify that this method can compensate the harmonic current correctly and validly.
Keywords
electric current control; power filters; Matlab; Simulink; a-b-c reference frame; current control; harmonic currents; nonlinear loads; reference compensation current estimation method; shunt active power filter control; three-phase active power filter; Active filters; Calculators; Harmonic analysis; Load modeling; Power harmonic filters; Simulation; active power filter; harmonic current; instantaneous reactive power theory; reference compensation current; simulation;
fLanguage
English
Publisher
ieee
Conference_Titel
Business Intelligence and Financial Engineering (BIFE), 2010 Third International Conference on
Conference_Location
Hong Kong
Print_ISBN
978-1-4244-7575-9
Type
conf
DOI
10.1109/BIFE.2010.24
Filename
5621729
Link To Document