• DocumentCode
    2851996
  • Title

    Noise reduction of switched reluctance machine

  • Author

    Gabsi, M. ; Camus, F. ; Loyau, T. ; Barbry, J.-L.

  • Author_Institution
    LESIR, ENS de Cachan, France
  • fYear
    1999
  • fDate
    36281
  • Firstpage
    263
  • Lastpage
    265
  • Abstract
    In this paper, the results relative to switched reluctance machine (SRM) acoustic noise are presented. The authors have particularly concentrated on the influence of power supply. Vibrations and radiated acoustic pressure have been reduced thanks to the flux instantaneous variation control, which was applied in limiting the duty cycle variations. Adding a simple electronic block inside the control unit enables, at any instant in time, to carry out this function of controlling the flux gradient. In order to quantify the contribution provided by this method, they have determined, by means of simulations and experimental measurements, the acoustic pressure levels as well as the performances of the machine
  • Keywords
    acoustic noise; machine control; machine testing; machine theory; noise abatement; reluctance machines; vibrations; SRM; acoustic noise reduction; duty cycle variations; flux gradient control; flux instantaneous variation control; radiated acoustic pressure; switched reluctance machine; vibrations; Acceleration; Accelerometers; Acoustic measurements; Acoustic noise; Frequency; Noise reduction; Pressure measurement; Reluctance machines; Vibration measurement; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Machines and Drives, 1999. International Conference IEMD '99
  • Conference_Location
    Seattle, WA
  • Print_ISBN
    0-7803-5293-9
  • Type

    conf

  • DOI
    10.1109/IEMDC.1999.769087
  • Filename
    769087