DocumentCode
2851996
Title
Noise reduction of switched reluctance machine
Author
Gabsi, M. ; Camus, F. ; Loyau, T. ; Barbry, J.-L.
Author_Institution
LESIR, ENS de Cachan, France
fYear
1999
fDate
36281
Firstpage
263
Lastpage
265
Abstract
In this paper, the results relative to switched reluctance machine (SRM) acoustic noise are presented. The authors have particularly concentrated on the influence of power supply. Vibrations and radiated acoustic pressure have been reduced thanks to the flux instantaneous variation control, which was applied in limiting the duty cycle variations. Adding a simple electronic block inside the control unit enables, at any instant in time, to carry out this function of controlling the flux gradient. In order to quantify the contribution provided by this method, they have determined, by means of simulations and experimental measurements, the acoustic pressure levels as well as the performances of the machine
Keywords
acoustic noise; machine control; machine testing; machine theory; noise abatement; reluctance machines; vibrations; SRM; acoustic noise reduction; duty cycle variations; flux gradient control; flux instantaneous variation control; radiated acoustic pressure; switched reluctance machine; vibrations; Acceleration; Accelerometers; Acoustic measurements; Acoustic noise; Frequency; Noise reduction; Pressure measurement; Reluctance machines; Vibration measurement; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Machines and Drives, 1999. International Conference IEMD '99
Conference_Location
Seattle, WA
Print_ISBN
0-7803-5293-9
Type
conf
DOI
10.1109/IEMDC.1999.769087
Filename
769087