• DocumentCode
    2852037
  • Title

    Measurement of the anisotropy fields for AMR sensors

  • Author

    Ouyang, J. ; Chen, S. ; Zhang, Y. ; Jin, F. ; Yang, X.F.

  • Author_Institution
    Dept. of Electron. Sci. & Technol., Huazhong Univ. of Sci. & Technol., Wuhan, China
  • fYear
    2011
  • fDate
    17-18 Nov. 2011
  • Firstpage
    1
  • Lastpage
    2
  • Abstract
    If the outputs of flipped AMR sensors are fitted by polynomial regression taking crossfields as the independent variables, anisotropy fields could be calculated by the ratio of zero-order items to second-order items. Test results verified that the anisotropy fields of the x, y, z axial AMR sensor (Honeywell HMR2300) were 0.778 mT, 0.829 mT, 0.820 mT, respectively. They were closed to the designed value (0.8 mT). And the crossfield errors were well compensated utilizing these field constants.
  • Keywords
    magnetic sensors; magnetic variables measurement; magnetoresistive devices; polynomials; regression analysis; AMR sensors; anisotropy field measurement; polynomial regression; second-order items; zero-order items; Anisotropic magnetoresistance; Coils; Films; Fitting; Magnetic field measurement; Magnetic sensors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electron Devices and Solid-State Circuits (EDSSC), 2011 International Conference of
  • Conference_Location
    Tianjin
  • ISSN
    Pending
  • Print_ISBN
    978-1-4577-1998-1
  • Electronic_ISBN
    Pending
  • Type

    conf

  • DOI
    10.1109/EDSSC.2011.6117748
  • Filename
    6117748