• DocumentCode
    2853843
  • Title

    Some diagnostic X-ray spectra and exposure measured using CdZnTe detector

  • Author

    Sumoto, Masao Mat ; Ajima, Satoshi Mi y ; Yamamoto, Akihide ; Yamazaki, Takaharu ; Kubota, Hideaki ; Kanamori, Hitoshi

  • Author_Institution
    Sch. of Allied Health Sci., Osaka Univ., Japan
  • Volume
    4
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    2513
  • Abstract
    The authors´ purpose is to measure directly some diagnostic X-ray spectra using a low-efficiency CdZnTe (CZT) detector developed recently and to find out the fittest response function of CZT detector to correct the measured spectre. Photon spectra produced by a single-phase 2-pulse diagnostic X-ray unit driven at 50 to 100 kV and a few mA, a mammographic X-ray unit at 25 to 32 kV and 3 times of 80 mAs and X-ray computed tomography (CT) scanners at 120 kV and 3 mA have been analyzed. Corrected photon spectra were compared with the diagnostic X-ray spectral data published by Bureau of Radiological Health (BRH) measured using a Ge detector. Exposures were calculated from the photon spectra and compared with measured using an ionization chamber. These results obtained using CZT detector agreed with the diagnostic X-ray spectral data of BRH and exposures obtained by the ionization chamber. Therefore the authors think that the CdZnTe detector is able to use for quality control and quality assurance of some diagnostic X-ray units
  • Keywords
    X-ray detection; cadmium compounds; computerised tomography; mammography; quality control; 25 to 120 kV; 3 mA; Bureau of Radiological Health; CdZnTe; CdZnTe detector; Ge; Ge detector; X-ray computed tomography scanners; corrected photon spectra; diagnostic X-ray spectra; diagnostic X-ray units; exposure measurement; ionization chamber; mammographic X-ray unit; medical diagnostic imaging; photon spectra; single-phase 2-pulse diagnostic X-ray unit; Attenuation measurement; Computed tomography; Electromagnetic scattering; Ionization chambers; Medical diagnostic imaging; Particle scattering; X-ray detection; X-ray detectors; X-ray imaging; X-ray scattering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-6465-1
  • Type

    conf

  • DOI
    10.1109/IEMBS.2000.901337
  • Filename
    901337