Abstract
This paper investigates the effects of changing the volume and position of permanent magnets in a single phase line-start permanent magnet motor. Using a time-stepped finite element model the breakdown of losses in an industrial prototype is presented. A number of new designs are investigated with the breakdown of losses used to illustrate the effects of design changes. The best new design is shown to be capable of improved performance when compared to the industrially designed prototype, with 24% less permanent magnet material and simplified construction. This design offers a 39% reduction in electrical costs when compared to the same frame size induction motor
Keywords
AC motors; finite element analysis; permanent magnet motors; PM position change; PM volume change; design changes effects; electrical costs reduction; line-start permanent magnet motor; losses breakdown; magnet dimensions; performance; single-phase; time-stepped finite element model; Building materials; Construction industry; Costs; Electric breakdown; Finite element methods; Induction motors; Magnetic materials; Permanent magnet motors; Permanent magnets; Prototypes;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Machines and Drives, 1999. International Conference IEMD '99
Conference_Location
Seattle, WA
Print_ISBN
0-7803-5293-9
Type
conf
DOI
10.1109/IEMDC.1999.769237
Filename
769237
Link To Document