• DocumentCode
    2855241
  • Title

    Evaluation of the 3D visualization of quantitative stereoelectroencephalographic information

  • Author

    Dillenseger, Jean-Louis ; Santos, Beatriz Sousa ; Teixeira, Pedro ; Nunes, Jose ; Ferreira, Carlos

  • Author_Institution
    Lab. Traitement du Signal et de l´´Image, Rennes I Univ., France
  • Volume
    4
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    2751
  • Abstract
    Stereoeletroencephalography (SEEG) has been used to define and understand the organization of epileptogenic zones of the brain. The fusion of the SEEG signals and the anatomy on a common referential is a possible method for the analysis of these signals. This work describes an experiment conducted with human observers in order to evaluate three different coding schemes used to visualize the magnitude of SEEG signal in the anatomical context
  • Keywords
    electroencephalography; medical signal processing; 3D visualization; SEEG signals fusion; anatomical context; brain epileptogenic zones; coding schemes evaluation; electrodiagnostics; human observers; quantitative stereoelectroencephalographic information; signals analysis; Anatomy; Brain; Electrodes; Epilepsy; Fusion power generation; Humans; Neurons; Signal analysis; Signal processing; Visualization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-6465-1
  • Type

    conf

  • DOI
    10.1109/IEMBS.2000.901430
  • Filename
    901430