DocumentCode :
2855688
Title :
Alignment of scalp electrode positions and MRI data sets. Weighted geometrical moments and removing outliers-compensation of incorrect digitization of head surface points
Author :
Kozinska, D. ; Nowinski, K.
Author_Institution :
Warsaw Univ., Poland
Volume :
4
fYear :
2000
fDate :
2000
Firstpage :
2846
Abstract :
Introducing weights into computation of geometrical moments is found to remarkably increase the accuracy of geometrical moments based alignment that determines the initial guess for the next stage of coregistration process. Introducing the removing outliers procedure and repeating the distance based alignment after that reduced the final alignment error (average distance) for our tested data sets. Introducing both these improvements increases reliability of the method, in the case of nonuniformly/inattentively digitized head surface points or incompatibility between them and MRI volume of the head, while the comfort of patients and medical personnel, as well as automacy are preserved
Keywords :
biomedical MRI; biomedical electrodes; image registration; medical image processing; MRI data sets; coregistration process; geometrical moments based alignment; head surface points; incorrect digitization compensation; removing outliers; scalp electrode positions; weighted geometrical moments; Biomedical electrodes; Data mining; Distributed computing; Electroencephalography; Gravity; Head; Magnetic resonance imaging; Personnel; Scalp; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1094-687X
Print_ISBN :
0-7803-6465-1
Type :
conf
DOI :
10.1109/IEMBS.2000.901460