    Achieving a smaller penumbra region for better planning in conformal radiotherapy by using a longitudinal magnetic field

  • Author

    Ramahi, Shada W. ; Naqvi, Shahid A. ; Chu, James

  • Author_Institution
    Rush Presbyterian St. Luke´´s Med. Center, Chicago, IL, USA
  • Volume
    4
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    3260
  • Abstract
    The problem of perturbing electronic fluence and dose deposition due to the presence of air cavities is addressed in this work. A uniform longitudinal magnetic field of 0.5 T strength is used to Increase the electronic fluence and to eliminate the broadened penumbra around air cavities, thus achieving better beam conformity. Monte Carlo code was used to simulate a 6 MV X-ray beam passing through air cavities of 2, 4 and 6 cm length. A point on the central axis 1 cm before the edge of the cavity was studied for the effect of the magnetic field on the electron fluence, hence on improving the dose profile. The improvement was found to depend on both beam and cavity size, for constant beam energy and magnetic strength constant, being better for larger cavities and smaller beams. There was a drastic improvement in the penumbra region in all the cases studied. The improvement was largest for 6 cm air cavity, decreasing from 3.65 cm down to 1.13 cm. For the cases studied, penumbra reduction, 62% on the average, was found to be independent of beam size. The electronic gyroradius, hence the degree of `confinement´ of electrons within the beam, is a function of electronic momentum and magnetic field strength. By keeping these two factors constant, conformity is expected to be the same in all the cases
  • Keywords
    Monte Carlo methods; X-ray applications; dosimetry; magnetic field effects; radiation therapy; 0.5 T; 1.13 to 6 cm; 6 MV; air cavities; better planning; cavity size; conformal radiotherapy; constant beam energy; dose deposition; dose profile improvement; longitudinal magnetic field; perturbing electronic fluence; smaller penumbra region; Electromagnetic scattering; Electron beams; Lesions; Lungs; Magnetic confinement; Magnetic fields; Magnetic heads; Neck; Particle scattering; X-ray scattering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-6465-1
  • Type

    conf

  • DOI
    10.1109/IEMBS.2000.901662
  • Filename
    901662