• DocumentCode
    2859203
  • Title

    EMC on AC motors-advice, tips and hints

  • Author

    Errath, Reinhold A.

  • Author_Institution
    ABB Industrie AG, Baden-Dattwil, Switzerland
  • fYear
    1997
  • fDate
    20-24 Apr 1997
  • Firstpage
    39
  • Lastpage
    61
  • Abstract
    Trends indicate that variable speed AC drives are already well established in the cement industry. However, as the use of these low maintenance drives, becomes more widespread, so do the associated problems. One such problem is that of electromagnetic interference (EI). EI can lead to de-rating when dimensioning the motor and modification of installation practices. In fact the need to take EI into consideration is no longer just recommended, it is rapidly becoming imperative. This paper deals with the background to these problems. Advice is also given on what is important for AC variable speed drive installation, plus recommendations are given to potential purchasers of AC drive systems
  • Keywords
    AC motor drives; cement industry; electromagnetic compatibility; electromagnetic interference; variable speed drives; AC motors; EMC; cement industry; electromagnetic interference; low maintenance drives; motor de-rating; variable speed AC drives; AC motors; Building materials; Cement industry; Electromagnetic compatibility; Electromagnetic interference; Engineering management; Hazards; Inverters; Torque control; Variable speed drives;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Cement Industry Technical Conference. 1997. XXXIX Conference Record., 1997 IEEE/PCA
  • Conference_Location
    Hershey, PA
  • ISSN
    1079-9931
  • Print_ISBN
    0-7803-3962-2
  • Type

    conf

  • DOI
    10.1109/CITCON.1997.599153
  • Filename
    599153