• DocumentCode
    2863760
  • Title

    High sensitivity vibration measurements with absolute calibration

  • Author

    Martinussen, Hanne ; Aksnes, Astrid ; Engan, Helge E.

  • Author_Institution
    Dept. of Electron. & Telecommun., Norwegian Univ. of Sci. & Technol., Trondheim
  • fYear
    2006
  • fDate
    21-26 May 2006
  • Firstpage
    1
  • Lastpage
    2
  • Abstract
    A heterodyne interferometer has been built to characterize surface vibrations between 0 - 600 MHz. The system has been used to measurements of high resolution absolute amplitude and phase on a SAW device at 25 MHz.
  • Keywords
    calibration; heterodyne detection; light interferometry; surface acoustic wave devices; vibration measurement; SAW device; absolute amplitude measurement; absolute calibration; frequency 0 MHz to 600 MHz; heterodyne interferometer; high sensitivity vibration measurement; phase measurement; surface vibrations; Calibration; Vibration measurement; (120.3180) Interferometry; (120.3940) Metrology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Lasers and Electro-Optics, 2006 and 2006 Quantum Electronics and Laser Science Conference. CLEO/QELS 2006. Conference on
  • Conference_Location
    Long Beach, CA
  • Print_ISBN
    978-1-55752-813-1
  • Electronic_ISBN
    978-1-55752-813-1
  • Type

    conf

  • DOI
    10.1109/CLEO.2006.4627773
  • Filename
    4627773