Title :
Structure comparison of buried permanent magnet synchronous motors for flux weakening operation
Author :
Teixeira, J.C. ; Chillet, C. ; YONNET, J.P.
Author_Institution :
Lab. d´´Electrotech. de Grenoble, France
Abstract :
The authors study the influence of two geometric variables, the air gap and the magnet thicknesses, by using a finite element method based package, thus avoiding the parametric representation. The fundamental component of each variable was used to determine power and speed. A sinusoidal no-load voltage as well as a sinusoidal current source justify this approach
Keywords :
finite element analysis; magnetic flux; permanent magnet motors; synchronous motors; air gap; buried permanent magnet synchronous motors; finite element method; flux weakening operation; magnet thicknesses; sinusoidal no-load voltage;
Conference_Titel :
Electrical Machines and Drives, 1993. Sixth International Conference on (Conf. Publ. No. 376)
Conference_Location :
Oxford
Print_ISBN :
0-85296-596-6