DocumentCode :
2868201
Title :
Dielectric loss of high voltage/high frequency transformers used in switching power supply for space
Author :
Kurita, Hiroshi ; Hasegawa, Taketoshi ; Shibuya, Yoshikazu ; Gohnai, Toshio ; Ohsuga, Hiroyuki ; Honda, Yukihiro
Author_Institution :
Mitsubishi Electr. Corp., Hyogo, Japan
fYear :
1988
fDate :
11-14 April 1988
Firstpage :
1120
Abstract :
The dielectric loss of a high-voltage/high-frequency transformer for a switching power supply is investigated. Measurements were made on a transformer designed to operate in a 100 kHz power supply. The voltages of the primary, secondary, and tertiary windings are 60 V, 950 V, and 1200 V, respectively. The results show that the dielectric loss constitutes a large part of loss at high frequency and that thermal runaway can occur unless some precautions are taken in the design. In particular, the amount of dielectric loss depends very strongly on the type of insulating materials used.<>
Keywords :
dielectric losses; power supplies to apparatus; power transformers; switching; 100 kHz; 1200 V; 60 V; 950 V; dielectric loss; high voltage/high frequency transformers; insulating materials; switching power supply; thermal runaway; Copper; Dielectric loss measurement; Dielectric losses; Dielectric measurements; Epoxy resins; Frequency; Iron; Loss measurement; Power supplies; Power transformer insulation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 1988. PESC '88 Record., 19th Annual IEEE
Conference_Location :
Kyoto, Japan
Type :
conf
DOI :
10.1109/PESC.1988.18252
Filename :
18252
Link To Document :
بازگشت