• DocumentCode
    2868902
  • Title

    Microwave chemical sensing using an 3–18 GHz wideband overmoded coaxial cable

  • Author

    Huang, Yu-Ting ; Hotopp, Kelly M. ; Dian, Brian C. ; Chappell, William J.

  • Author_Institution
    Department of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA
  • fYear
    2012
  • fDate
    17-22 June 2012
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    A room-temperature chirped pulse Fourier transform microwave spectrometer was recently demonstrated using a WRD750 double ridge waveguide. The operation frequency range, 7.5 GHz to 18 GHz, is limited by the waveguide, and the effective sensing area is confined within the small region between the two ridges. This paper shows a new overmoded coaxial cable spectrometer design utilizing a Hamming function tapered transmission line method that provides smooth tapering to increase the spectrometer´s bandwidth by 43%. The successful spectra measurement in this paper proves the application of using the overmoded coaxial cable as a chemical sensor.
  • Keywords
    Chirp; Conductors; Wideband; Coaxial cable; Hamming function; microwave spectroscopy; sensor; spectrometer; tapered transmission line;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Symposium Digest (MTT), 2012 IEEE MTT-S International
  • Conference_Location
    Montreal, QC, Canada
  • ISSN
    0149-645X
  • Print_ISBN
    978-1-4673-1085-7
  • Electronic_ISBN
    0149-645X
  • Type

    conf

  • DOI
    10.1109/MWSYM.2012.6259724
  • Filename
    6259724