• DocumentCode
    2871380
  • Title

    Revisions of the periodic conformance testing procedures in the NEMA MW 1000 magnet wire standard

  • Author

    Barta, Donald J.

  • Author_Institution
    Phelps Dodge Magnet Wire Co., Fort Wayne, IN
  • fYear
    2005
  • fDate
    26-26 Oct. 2005
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In the last few years, there has been a considerable amount of activity generated in the NEMA 6-MW Technical Committee due to a change in philosophy regarding the periodic conformance testing of magnet wire products. In the past, the periodic conformance tests have been designed around the special testing of a few standard AWG sizes, to define the unique properties of a particular magnet wire product type. These periodic conformance tests have been used to describe the uniqueness of the particular insulation system of the MW type, rather than to describe the expected performance of different wire sizes in these periodic conformance tests. The need to perform these periodic conformance tests on other wire sizes has created the demand for a new approach
  • Keywords
    cable testing; conformance testing; insulated wires; magnetic materials; NEMA MW 1000 magnet wire standard; Technical Committee; conformance testing; insulation system; Aluminum; Cable insulation; Dielectric breakdown; Insulation testing; Magnetic properties; Oil insulation; Performance evaluation; System testing; Temperature dependence; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference and Electrical Manufacturing Expo, 2005. Proceedings
  • Conference_Location
    Indianapolis, IN
  • Print_ISBN
    0-7803-9145-4
  • Type

    conf

  • DOI
    10.1109/EEIC.2005.1566246
  • Filename
    1566246