• DocumentCode
    2871663
  • Title

    Investigation of temperature rise and permissible load current of water-cooled generators with blockage of hollow sub-conductors

  • Author

    Naghashan, M.R. ; Shoar, D. Hekmat

  • Author_Institution
    Power & Water Inst. of Technol., Tehran
  • fYear
    2005
  • fDate
    26-26 Oct. 2005
  • Firstpage
    85
  • Lastpage
    88
  • Abstract
    Temperature rise of insulation can be due to the blockage of the hollow sub-conductors in water-cooled bars. The objective of this project is to make a software simulator to analyze the problem in water-cooled generators in Iran. An experimental setup is constructed to recognize the hollow sub-conductor blockage and its effect on the permissible load current of the generator bar. Results of experiments are used to develop an evaluation software model. The model is applied in air and in hydrogen medium. Measured temperatures of various points on the generator bar show that the hot spot of the insulation can not be detected easily by normal slot RTDs in the machine
  • Keywords
    bars; cooling; electric generators; electric machine analysis computing; hydrogen; machine insulation; temperature measurement; Iran; RTD; air medium; hydrogen medium; insulation temperature rise; software simulator; sub-conductor blockage; temperature measurement; water-cooled generator bar; Bars; Character generation; Conductors; Induction generators; Insulation; Land surface temperature; Power generation; Temperature measurement; Temperature sensors; Water;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference and Electrical Manufacturing Expo, 2005. Proceedings
  • Conference_Location
    Indianapolis, IN
  • Print_ISBN
    0-7803-9145-4
  • Type

    conf

  • DOI
    10.1109/EEIC.2005.1566264
  • Filename
    1566264