Annealing temperature dependent strength of polysilicon measured using a novel tensile test structure
Author :
Kamiya, S. ; Kuypers, J. ; Trautmann, A. ; Ruther, P. ; Paul, O.
Author_Institution :
Inst. for Microsyst. Technol., Freiburg Univ., Germany
Abstract :
Polysilicon is commonly used as a structural material of MEMS after being deposited at a temperature below 600°C and annealed at a temperature around 1000°C to remove the residual stress. On the other hand, polysilicon can be also deposited at a temperature higher than 600°C. We have examined the strength of polysilicon films obtained with different processing temperatures using a new efficient tensile test structure with plural specimens bridging the gap of a silicon substrate. Films deposited at 560°C had the highest strength when annealed at 850°C. Films deposited at 625°C and annealed at 1050°C were weaker than those deposited at 560°C and annealed at 1050°C.
Keywords :
annealing; chemical vapour deposition; elemental semiconductors; internal stresses; micromechanical devices; semiconductor growth; semiconductor thin films; silicon; tensile strength; tensile testing; 1050 degC; 560 degC; 625 degC; 850 degC; MEMS; Si; annealing temperature; chemical vapour deposition; microelectromechanical system; polysilicon films; polysilicon strength; silicon substrate; structural material; tensile test structure; Amorphous materials; Annealing; Crystallization; Micromechanical devices; Residual stresses; Silicon; Temperature dependence; Temperature sensors; Tensile stress; Testing;
Conference_Titel :
Micro Electro Mechanical Systems, 2004. 17th IEEE International Conference on. (MEMS)
Print_ISBN :
0-7803-8265-X
DOI :
10.1109/MEMS.2004.1290553