DocumentCode :
2872547
Title :
Use of test procedures for resin tank maintenance
Author :
Laurenty, David A. ; Alewine, Kevin B. ; Frost, Nancy E.
fYear :
2005
fDate :
26-26 Oct. 2005
Firstpage :
361
Lastpage :
364
Abstract :
The performance of resins for electrical insulation systems over time is dependent on the stability of the resin. There are standardized tests that can be performed to monitor the resin and adjust it, as necessary, to maintain resin integrity. This paper will discuss some of the tests that are most commonly utilized in the industry, as well as discussion of the meaning of the results of these tests. The resin manufacturer should be consulted prior to any adjustments to the tank of resin
Keywords :
condition monitoring; insulation testing; maintenance engineering; resins; tanks (containers); electrical insulation system; industrial testing; monitoring; resin tank maintenance; stability; Chemicals; Dielectrics and electrical insulation; Electric resistance; Manufacturing; Monitoring; Resins; Solvents; Stability; Testing; Thermal resistance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation Conference and Electrical Manufacturing Expo, 2005. Proceedings
Conference_Location :
Indianapolis, IN
Print_ISBN :
0-7803-9145-4
Type :
conf
DOI :
10.1109/EEIC.2005.1566321
Filename :
1566321
Link To Document :
بازگشت