Title :
Accurate calorimetric power loss measurement for efficient power converters
Author :
Kamei, Ryo ; Kim, Tae-Woong ; Kawamura, Atsuo
Author_Institution :
Yokohama Nat. Univ., Yokohama, Japan
Abstract :
The calorimetric power loss measurement is introduced for securing both higher accuracy measurement and faster measurement time. To reduce measurement accuracy error, copper leakage loss of wires is taken into consideration. To save measurement time, balancing relation between flow rate and temperature rise is also taken into consideration. Flow rate and temperature rise are largely dependent on sensor resolutions. To satisfy faster measurement time, high resolution sensors are extremely required. By balancing relation between flow rate and temperature rise, the maximized flow rate can be calculated. This effectiveness is verified through theoretical and experimental analyses.
Keywords :
calorimetry; electrical faults; energy conservation; flow sensors; loss measurement; measurement errors; power convertors; power measurement; wires (electric); calorimetric power loss measurement; copper leakage loss; flow rate; high resolution sensors; measurement accuracy error reduction; measurement time; power converters; temperature rise; wires; Accuracy; Copper; Heating; Loss measurement; Power measurement; Temperature measurement; Time measurement;
Conference_Titel :
IECON 2011 - 37th Annual Conference on IEEE Industrial Electronics Society
Conference_Location :
Melbourne, VIC
Print_ISBN :
978-1-61284-969-0
DOI :
10.1109/IECON.2011.6119474