    Reduction of transformer rated power and line current harmonics in a primary switched converter system for traction applications

  • Author

    Östlund, S.

  • Author_Institution
    R. Inst. of Technol., Stockholm, Sweden
  • fYear
    1993
  • fDate
    13-16 Sep 1993
  • Firstpage
    112
  • Abstract
    The transformer of traction vehicles fed from a 15 kV, 162 /3 Hz AC supply has, due to the low frequency, a substantial weight. By using a primary switched converter system the transformer frequency can be increased and a reduction of the weight is possible. For a fixed frequency the transformer weight is determined mainly by its rated power. The rated power has to be about twice the transmitted power which limits the weight reduction. If the four-quadrant converter of the primary switched system is used for modulation of the line current, the transformer has to operate at a varying frequency. It is shown that the transformer rated power then can be reduced by approximately 40% compared to constant frequency. The current modulation principle requires a fairly high operating frequency of the four-quadrant converter. Current modulation has with regard to line current harmonics been compared with a principle for harmonic reduction based on a division of the primary converter into several converters connected in series
  • Keywords
    electric current control; harmonics; power convertors; traction; 15 kV; 16.67 Hz; 4 MW; AC supply; computer simulations; current modulation principle; four-quadrant converter; line current harmonics; primary switched converter system; rated power; traction applications; transformer rated power;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Power Electronics and Applications, 1993., Fifth European Conference on
  • Conference_Location
    Brighton
  • Type

    conf

  • Filename
    265062