• DocumentCode
    2874101
  • Title

    A novel multiple LFM signals detection method

  • Author

    You, He ; Feng, Su ; Changwen, Qu

  • Author_Institution
    Res. Inst. of Inf. Fusion, Naval Aeronaut. Eng. Acad., China
  • fYear
    2004
  • fDate
    18-21 Aug. 2004
  • Firstpage
    818
  • Lastpage
    821
  • Abstract
    The Wigner-Ville distribution (WVD) Hough transform could effectively detect several linear-frequency modulated (LFM) signals in low signal-noise ratio (SNR) environment. However, when the energy of these LFM signals diverge greatly, it is quite difficult to detect all LFM signals with the WVD-Hough transform at the same time, because the platform of strong signals will cover weak signals. All LFM signals can be detected with the "CLEAN" technique, but this solution can only be achieved at the cost of a large increase in computational load. In this paper, a signal detection method based on WVD and binary integration in Hough transform parameter space is proposed according to the WVD-Hough transform. Using this method, strong signals as well as the weak signals covered by the strong signals could be detected simultaneously. It means that this method has high practicable value. Simulation results verify the effectiveness of this method.
  • Keywords
    Hough transforms; Wigner distribution; frequency modulation; signal detection; Hough transform; Wigner-Ville distribution; binary integration; linear-frequency modulated signals; multiple LFM signals detection; signal strength; Amplitude modulation; Chirp modulation; Costs; Energy resolution; Gaussian noise; Shape; Signal detection; Signal resolution; Time frequency analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave and Millimeter Wave Technology, 2004. ICMMT 4th International Conference on, Proceedings
  • Print_ISBN
    0-7803-8401-6
  • Type

    conf

  • DOI
    10.1109/ICMMT.2004.1411655
  • Filename
    1411655