DocumentCode
2877504
Title
Emittance measurements at the 100 keV beam stage of the injector linac of the IFUSP microtron
Author
Silva, T.F. ; Malafronte, A.A. ; Martins, M.N.
Author_Institution
Inst. de Fisica da Univ. de Sao Paulo, Sao Paulo
fYear
2007
fDate
25-29 June 2007
Firstpage
3898
Lastpage
3900
Abstract
The injector linac consists of a 100-keV electron gun, a beam conforming stage, and two acceleration structures. The beam focalization is made by solenoids, and correcting coils are provided for steering. In this work we describe the beam emittance measurement on the beam conforming stage. Some results are shown. The injector linac consists of a beam conforming stage, with chopper and buncher systems, and two acceleration structures [2] (the first one with variable beta, and the second one divided into two parts with different beta). There is a 3-mm diameter collimator at the entrance to the first acceleration structure.
Keywords
collimators; electron guns; linear accelerators; microtrons; particle beam bunching; particle beam focusing; particle beam injection; solenoids; IFUSP microtron injector linac; acceleration structures; beam conforming stage; beam emittance measurement; beam focalization; buncher systems; chopper systems; coils; collimator; electron gun; preaccelerated beam; solenoids; Acceleration; Cathodes; Coils; Collimators; Electron beams; Fluorescence; Lenses; Linear particle accelerator; Particle beams; Solenoids;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2007. PAC. IEEE
Conference_Location
Albuquerque, NM
Print_ISBN
978-1-4244-0916-7
Type
conf
DOI
10.1109/PAC.2007.4439930
Filename
4439930
Link To Document