Title :
Characterization of tissue optical parameters in the region of 1-2 μm
Author :
Nishimura, Goro ; Tamura, Mamom
Author_Institution :
Biophys. Lab., Hokkaido Univ., Sapporo, Japan
Abstract :
The time-of-flight (TOF) method and the diffuse reflectance (DR) method were applied for the characterization of optical parameters in living tissue in the region of 1-2 μm. The absorption coefficient obtained by the TOF method was consistent with the content of water in the tissue. The DR measurement indicates the very large attenuation in the wavelength region above 1.4 μm. In this region, it is suggested that the optical transport does not diffuse well and it is localized at the light source.
Keywords :
absorption coefficients; bio-optics; biological tissues; biomedical measurement; 1 to 2 micron; absorption coefficient; diffuse reflectance method; light source; living tissue; optical parameters characterization; time-of-flight method; water content; Absorption; Attenuation measurement; Biomedical optical imaging; Light scattering; Light sources; Optical attenuators; Optical scattering; Particle scattering; Ultrafast optics; Wavelength measurement;
Conference_Titel :
Biophotonics, 2004. APBP 2004. The Second Asian and Pacific Rim Symposium on
Print_ISBN :
0-7803-8676-0
DOI :
10.1109/APBP.2004.1412313