• DocumentCode
    2880754
  • Title

    Electrical-Optical High Speed Serial Server Scalability Link

  • Author

    de Araujo, D.N. ; Mutnury, B. ; Cases, M.

  • Author_Institution
    Ansoft Corp., Austin
  • fYear
    2007
  • fDate
    May 29 2007-June 1 2007
  • Firstpage
    1646
  • Lastpage
    1652
  • Abstract
    Increased demand for performance has driven a significant increase in the data rate and the complexity of today´s high speed systems and interconnect. While skin effects and dielectric loss are significant sources of limitation of current high-speed digital communication (Broomall and Van Deusen, 1997), equalization at the transmitter, receiver, and interconnect has extended the range and performance of copper links. Electrical copper links are typically used to interconnect multiple processor subsystems to build symmetric multi-processor (SMP) systems, as well as to connect input/output (I/O) subsystems across relative long distances. During the electrical design and validation of a highly scalable, modular SMP server (Brown and Dhawan, 2002) with data rates of 3.2 GT/s (GigaTransfers per second) and higher, a test vehicle was designed and built. The goal was to characterize and contrast an all-copper external cable and a copper-to-optical interconnect technology, and to understand how to achieve the overall system design goals from the perspective of link performance, electrical challenges, and physical design constraints. Key design parameters have been modeled and correlated with laboratory measurements such as AC coupling capacitor selection and layout optimization, via stub, back-drilling, and signal launch effects. Modeling techniques and correlation challenges are discussed in this paper.
  • Keywords
    copper; multiprocessing systems; multiprocessor interconnection networks; network servers; optical interconnections; telecommunication links; Cu; SMP server; copper-to-optical interconnect technology; data rate; dielectric loss; electrical copper links; electrical design; electrical-optical high speed serial server scalability link; high speed system; input/output subsystems; multiple processor subsystems; skin effects; symmetric multiprocessor systems; Copper; Dielectric losses; Digital communication; Performance loss; Propagation losses; Scalability; Skin effect; Testing; Transmitters; Vehicles;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic Components and Technology Conference, 2007. ECTC '07. Proceedings. 57th
  • Conference_Location
    Reno, NV
  • ISSN
    0569-5503
  • Print_ISBN
    1-4244-0985-3
  • Electronic_ISBN
    0569-5503
  • Type

    conf

  • DOI
    10.1109/ECTC.2007.374015
  • Filename
    4250101