DocumentCode
2883110
Title
New corrector system for the Fermilab Booster
Author
Prebys, E.J. ; Drennan, C.C. ; Harding, D.J. ; Kashikhin, V. ; Lackey, J.R. ; Makarov, A. ; Pellico, W.A.
Author_Institution
FNAL, Batavia
fYear
2007
fDate
25-29 June 2007
Firstpage
467
Lastpage
469
Abstract
We present an ambitious ongoing project to build and install a new corrector system in the Fermilab 8 GeV booster. The system consists of 48 corrector packages, each containing horizontal and vertical dipoles, normal and skew quadrupoles, and normal and skew sextupoles. Space limitations in the machine have motivated a unique design, which utilizes custom wound coils around a 12 pole laminated core. Each of the 288 discrete multipole elements in the system will have a dedicated power supply, the output current of which is controlled by an individual programmable ramp. This paper describes the physics considerations which drove the design, as well as issues in the control of the system.
Keywords
particle accelerator accessories; synchrotrons; Fermilab Booster; corrector system; dipoles; electron volt energy 8 GeV; quadrupoles; sextupoles; Acceleration; Coils; Control systems; Current supplies; Magnets; Packaging machines; Particle beams; Prototypes; Resonance; Wounds;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2007. PAC. IEEE
Conference_Location
Albuquerque, NM
Print_ISBN
978-1-4244-0916-7
Type
conf
DOI
10.1109/PAC.2007.4440247
Filename
4440247