  • Abstract
    Aim of this study was to evaluate quantitative parameters for inter- and intra-ventricular dyssynchronicity measurement. 10 patients with severely reduced left ventricular function (LVF) and variable QRS duration (70% had left bundle branch blockation; LBBB) and six healthy subjects (control) were examined with cine magnetic resonance imaging. The phase differences between the left and right ventricle were estimated from the endo- and epicardial contours of the full left and right ventricle in short axis slices for the whole cardiac cycle. Inter-ventricular asynchronicity (INTER) and intraventricular asynchronicity (INTRA) were significantly higher in patients with reduced L VF as compared to the control group independently from the presence of a LBBB. INTRA but not INTER could discriminate patients with and without LBBB. We found two clinically very promising parameters describing the phase difference of the left and right ventricle.
  • Keywords
    biomedical MRI; cardiology; medical image processing; cardiac cycle; cardiac magnetic resonance imaging; cine magnetic resonance imaging; endocardial contours; epicardial contours; inter-ventricular asynchronicity; inter-ventricular dyssynchronization; intra- ventricular asynchronicity; intra-ventricular dyssynchronization; left bundle branch blockation; left ventricle; phase difference; right ventricle; severely reduced left ventricular function; variable QRS duration; Bioinformatics; Cardiology; Heart; Information processing; Magnetic resonance imaging; Magnetic variables control; Medical control systems; Noise reduction; Pacemakers; Phase estimation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computers in Cardiology, 2003
  • ISSN
    0276-6547
  • Print_ISBN
    0-7803-8170-X
  • Type

    conf

  • DOI
    10.1109/CIC.2003.1291262
  • Filename
    1291262