The use of a standard radiating source to predict radiated emissions in a GTEM cell (30 MHz-1 GHz)
Author
Nothofer, A. ; Marvin, A.C. ; Dawson, L.
fYear
1999
fDate
1999
Firstpage
42552
Lastpage
42555
Abstract
This paper provides with a method to determine the uncertainty margins due to cross-polar coupling in GTEM cell measurements. These margins vary over the volume of the cell. For this paper only the electric dipole moments have been considered