• DocumentCode
    2884388
  • Title

    The use of a standard radiating source to predict radiated emissions in a GTEM cell (30 MHz-1 GHz)

  • Author

    Nothofer, A. ; Marvin, A.C. ; Dawson, L.

  • fYear
    1999
  • fDate
    1999
  • Firstpage
    42552
  • Lastpage
    42555
  • Abstract
    This paper provides with a method to determine the uncertainty margins due to cross-polar coupling in GTEM cell measurements. These margins vary over the volume of the cell. For this paper only the electric dipole moments have been considered
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Measurement Dissemination by Transfer Methods (Ref. No. 1999/048), IEE Seminar
  • Conference_Location
    London
  • Type

    conf

  • DOI
    10.1049/ic:19990252
  • Filename
    771969