DocumentCode
2884905
Title
Comparison of micro fabricated C and S bend shape SU-8 polymer waveguide of different bending diameters for maximum sensitivity
Author
Tripathi, Rakesh ; Prabhakar, Amit ; Mukherji, Soumyo
Author_Institution
WRCBB, Dept of Biosciences and Bioengineering, IIT Bombay, Mumbai 400 076, India
fYear
2012
fDate
7-10 March 2012
Firstpage
228
Lastpage
231
Abstract
In this study C and S bend shape SU-8 polymer optical waveguides of different bending diameters have been microfabricated to experimentally investigate the effect of bending on the sensitivity of the waveguides. The real-time change in absorbance with change in refractive index varying from 1.33 to 1.38 of external medium is observed at wavelength 530 nm. It is observed that in both C and S shape, the sensitivity increases with the decreasing bending diameter. After an optimum value any further decrease in bending diameter reduces the sensitivity of waveguides. Maximum sensitivity observed with C shape is 5.35 ΔA / RIU and S shape is 13.04 ΔA / RIU, which is more than twice as compared to C shape.
Keywords
Evanescent wave; Optical waveguide; S shaped polymer waveguide; SU-8;
fLanguage
English
Publisher
ieee
Conference_Titel
Physics and Technology of Sensors (ISPTS), 2012 1st International Symposium on
Conference_Location
Pune, India
Print_ISBN
978-1-4673-1040-6
Type
conf
DOI
10.1109/ISPTS.2012.6260931
Filename
6260931
Link To Document