• DocumentCode
    2886815
  • Title

    Some possibilities of reduction of working voltage compact generators negative air ions oxygen

  • Author

    Dmitriev, A.E. ; Toropchin, V.I. ; Trufyakov, V.V.

  • Author_Institution
    Saratov State Tech. Univ., Saratov, Russia
  • fYear
    2010
  • fDate
    22-23 Sept. 2010
  • Firstpage
    318
  • Lastpage
    323
  • Abstract
    Experimentally studied the possibility of reducing the high voltage in a modified during the experiment, a mock-IV-1 "Hippocrates". This device is used as a source of negative air ions of oxygen to compensate for the positive ions in rooms with high-voltage equipment. Generator Negative air ions, the anode voltage, ions concentration, high-voltage devices in the laboratory. The possibility of reducing the voltage on the emitter of the generator air ions of oxygen through the optimization of its design from 22 to 16 KV at a concentration of negative air ions 3.1 * 104 cm-3.
  • Keywords
    electric generators; high-voltage techniques; negative ions; optimisation; Hippocrate; negative air ions oxygen; optimization; voltage 22 kV to 16 kV; voltage compact generators; Anodes; Generators; Ions; Laboratories; Optimization; Oxygen;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Actual Problems of Electron Devices Engineering (APEDE), 2010 International Conference on
  • Conference_Location
    Saratov
  • Print_ISBN
    978-1-4244-6954-3
  • Type

    conf

  • DOI
    10.1109/APEDE.2010.5624100
  • Filename
    5624100