• DocumentCode
    2887162
  • Title

    Microprocessor Control of Power Plants-Report from a Large Telephone Office Installation

  • Author

    Eriksson, M ; Svensk, R.

  • Author_Institution
    Ericsson Power System, RIFA AB, 163 81 Stockholm, SWEDEN
  • fYear
    1984
  • fDate
    4-7 Nov. 1984
  • Firstpage
    378
  • Lastpage
    382
  • Abstract
    A paper describing a general purpose control and monitoring system for power plants ERICSSON ENERGY-MASTER was presented at INTELEC 83. The system has been implemented in a power plant installation in Stockholm during 1983. This paper describes some properties and features of the installation, such as: * System configuration: main computer with distributed microcomputers, communication link and separate hardwired alarm functions. * Step connection facility. * Automatic battery charging * Autonomous operation when computer is down * Intelligent alarm functions with diagnostics. * Remote operation and control Practical use of the described functions are followed up and explained. Examples of tables and messages are given. Experience from putting a complex system of many distributed processors into operation is reported.
  • Keywords
    Automatic control; Batteries; Communication system control; Computerized monitoring; Control systems; Distributed computing; Microcomputers; Microprocessors; Power generation; Telephony;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications Energy Conference, 1984. INTELEC '84. International
  • Conference_Location
    New Orleans, LA, USA
  • Type

    conf

  • DOI
    10.1109/INTLEC.1984.4794154
  • Filename
    4794154