Abstract :
The closed loop control problem of gas distribution network is investigated in this paper. This system involves two control loops where the secondary part of the process (the inner loop) has a negligible delay while the primary loop (the outer loop) has a significant and time variant delay. The use of Smith Predictor in the outer loop of cascade control system compensates the negative effect of time delay in the performance of the controller. Due to sensitivity of Smith Predictor to modeling error, this paper focuses on an accurate identification method to eliminate this problem. Simulation results for Khouzestan gas distribution network as a case study are included in this paper to illustrate the proposed technique.
Keywords :
cascade control; closed loop systems; compensation; delays; gas industry; identification; natural gas technology; pressure control; process control; Smith predictor; cascade control system; closed loop control; compensation; gas distribution network; identification; industrial automation; pressure control; simulation; time variant delay; Automatic control; Automation; Cities and towns; Control systems; Delay effects; Delay systems; Natural gas; Pressure control; Process control; Three-term control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Information, Decision and Control, 2007. IDC '07
Conference_Location :
Adelaide, Qld.
Print_ISBN :
1-4244-0902-0
Electronic_ISBN :
1-4244-0902-0
Type :
conf
DOI :
10.1109/IDC.2007.374561
Filename :
4252513
Link To Document :
بازگشت