DocumentCode
2888630
Title
High QE photocathodes performance during operation at FLASH / PITZ photoinjectors
Author
Monaco, L. ; Michelato, P. ; Pagani, C. ; Sertore, D.
Author_Institution
INFN Milano, Segrate
fYear
2007
fDate
25-29 June 2007
Firstpage
2763
Lastpage
2765
Abstract
Since 1998, the DESY photoinjectors at FLASH and PITZ routinely use high quantum efficiency (QE) photocathodes produced at LASA (INFN-Milano). To further understand the photocathode behavior during beam operation, photocathode QE measurements have been performed at different operating conditions in both photoinjectors. The analysis of these measurements will be used to improve the photocathode preparation procedures and deepen our understanding of the photocathode properties. An important goal is to further increase their lifetime and to preserve a high beam quality during the operation in the RF gun of the photoinjector.
Keywords
accelerator RF systems; particle beam injection; photocathodes; storage rings; DESY; FLASH photoinjectors; LASA; PITZ photoinjectors; RF gun; high beam quality; high quantum efficiency photocathodes; operating conditions; Cathodes; Dark current; Guns; Monitoring; Performance evaluation; Plugs; Production; Radio frequency; Response surface methodology; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2007. PAC. IEEE
Conference_Location
Albuquerque, NM
Print_ISBN
978-1-4244-0916-7
Type
conf
DOI
10.1109/PAC.2007.4440568
Filename
4440568
Link To Document