DocumentCode :
2891526
Title :
Development of injection voltage technique for absolute calibration of inductive voltage divider
Author :
Saxena, A.K. ; Dhar, R.N. ; Dahake, S.L. ; Chandra, K.
Author_Institution :
National Physical Laboratory
fYear :
1988
fDate :
7-10 June 1988
Firstpage :
63
Lastpage :
64
Abstract :
Experimental set-up used for the absolute calibration of inductive voltage divider using injection voltage is described. The total uncertainty obtained in the calibration is of the order of 1x10 -8 at 1kHz.
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements, 1988. CPEM 88 Digest. 1988 Conference on
Conference_Location :
Ibaraki, Japan
Type :
conf
DOI :
10.1109/CPEM.1988.671177
Filename :
671177
Link To Document :
بازگشت