DocumentCode :
2895383
Title :
Final adjustment of the magnetic field of the LNLS VUV undulator
Author :
Tosin, G. ; Citadini, J.F. ; Basílio, R. ; Potye, M.
Author_Institution :
LNLS, Campinas
fYear :
2007
fDate :
25-29 June 2007
Firstpage :
917
Lastpage :
919
Abstract :
The first insertion device built at LNLS was an elliptically polarized undulator, designed to cover the vacuum ultraviolet and the soft X-ray spectrum. Its magnetic characterization was done using two techniques: Hall probes, for local field measurements, and rotating coil, operating in a way similar to flip-coil, to determine the integrated multipoles. Final results for the phase errors as well as the procedures used to correct the integrated multipoles are presented.
Keywords :
X-ray spectra; beam handling techniques; magnetic fields; synchrotrons; ultraviolet spectra; wigglers; Hall probes; LNLS vacuum ultraviolet undulator; elliptically polarized undulator; flip-coil; integrated multipoles; local field measurements; magnetic field; phase errors; soft X-ray spectrum; Coils; Hall effect devices; Magnetic field measurement; Magnetic fields; Magnetic flux; Magnetization; Optical polarization; Permeability; Rotation measurement; Undulators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2007. PAC. IEEE
Conference_Location :
Albuquerque, NM
Print_ISBN :
978-1-4244-0916-7
Type :
conf
DOI :
10.1109/PAC.2007.4440934
Filename :
4440934
Link To Document :
بازگشت