Title :
A Precision 60 GHz Open Resonator System for Permittivity and Loss Tangent Measurement of Low Absorbing Materials
Author :
Afsar, M.N. ; Matsui, T. ; Hua Chi
Author_Institution :
Tufts University
Abstract :
An automated open resonator system is designed and constructed to operate at 60 GHz for loss tangent and permittivity measurement of materials with loss tangent value as low as 10 micro-radians. This is accomplished by the use of a high Q cavity together with a synthesized 60 GHz Gunn oscillator source, a 56 GHz Gunn local oscillator both phase locked to a frequency standard and the heterodyne detection.
Conference_Titel :
Precision Electromagnetic Measurements, 1988. CPEM 88 Digest. 1988 Conference on
Conference_Location :
Ibaraki, Japan
DOI :