Abstract :
X-band klystron research and development has been underway at SLAC for over two decades culminating in the current workhorse X-band RF source, the XL-4. The XL-4 traveling wave output structure consists of 4-cells and will be extended to 6-cells to reduce breakdown and further improve upon the klystron´s robustness. Simulations show the gradient can be reduced by roughly 25% and that the cavity is stable. The new output cavity will be cold tested and implemented on an existing XL-4 in the near future.
Keywords :
klystrons; travelling wave tubes; 4-cells; Q 6-cell X-band klystron; SLAC; X-band RF source; XL-4 traveling wave output structure; current workhorse; output cavity; Accuracy; Cavity resonators; Frequency measurement; Geometry; Klystrons; Mathematical model; Power generation; Kroll-Yu; Q; cavity; gradient; klystron; multi-cell; simulation; stability; x-band;