Application of Clock Error Prediction for Digital Communications
Author :
Stover, Harris A.
Author_Institution :
Defense Communications Engineerirg Center, 1860 Wiehle Ave., Reston, VA 22091
Volume :
3
fYear :
1983
fDate :
Oct. 31 1983-Nov. 2 1983
Firstpage :
731
Lastpage :
737
Abstract :
Survivability of digital defense communications can be enhanced by a free-running clock mode of operation for use when the normal timing modes are not available. Usefulness of a free-running mode of timing depends on stability and accuracy. The cost of using cesium clocks throughout the network could be very large, but much less expensive quartz-crystal and rubidium clocks could be used for many applications if errors during a free-running period (following a calibration period) can be predicted and removed with sufficient accuracy for a long enough period of time. This paper discusses one relatively simple recursive method for making such predictions.
Keywords :
Calibration; Clocks; Communication switching; Costs; Difference equations; Digital communication; Military communication; Signal processing; Stability; Timing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Military Communications Conference, 1983. MILCOM 1983. IEEE
Conference_Location :
Washington, DC, USA
Type :
conf
DOI :
10.1109/MILCOM.1983.4794797