DocumentCode
2901011
Title
High power tests of first input couplers for cornell erl injector cavities
Author
Veshcherevich, V. ; Belomestnykh, S. ; Quigley, P. ; Reilly, J. ; Sears, J. ; Möller, W.D.
Author_Institution
Cornell Univ., Ithaca
fYear
2007
fDate
25-29 June 2007
Firstpage
2355
Lastpage
2357
Abstract
The first two RF power couplers for the ERL injector, currently under construction at Cornell University, have been fabricated. The couplers were assembled in the liquid nitrogen cryostat, built for their tests. A 15 kW CW IOT transmitter was available for coupler tests. A resonant ring was used for an additional increase of power. The couplers were successfully tested up to the goal power level of 50 kW CW. However, the first pair of couplers showed an excessive temperature rise at some points. Therefore, minor changes in the design have been done to improve cooling.
Keywords
accelerator RF systems; accelerator cavities; cryostats; linear accelerators; particle beam injection; photocathodes; CW IOT transmitter; Cornell ERL injector cavities; Energy Recovery Linac; RF power couplers; cooling; liquid nitrogen cryostat; photocathode DC gun; power 15 kW; power 50 kW; resonant ring; Ceramics; Coaxial components; Cooling; Couplers; Nitrogen; Optical coupling; Radio frequency; Structural beams; Temperature; Testing;