DocumentCode
2901032
Title
An improved SF6 system for the FXR induction linac blumlein switches
Author
DeHope, W.J. ; Griffin, K.L. ; Kihara, R. ; Ong, M.M. ; Ross, T.O.
Author_Institution
Lawrence Livermore Nat. Lab., Livermore
fYear
2007
fDate
25-29 June 2007
Firstpage
2361
Lastpage
2363
Abstract
The now-mature FXR (flash X-ray) radiographic facility at Lawrence Livermore National Laboratory will be briefly described with emphasis on its pulsed power system. The heart of each accelerating cell´s pulse-forming Blumlein is its sulfur hexafluoride-based triggered closing switch. FXR´s recent upgrade to a recirculating SF6 gas reclamation system will be described and the resulting accelerator performance and reliability improvements documented. This was accompanied by a detailed switch breakdown study on FXR´s test stand and the recent analysis of the resulting statistics will be shown.
Keywords
X-ray applications; linear accelerators; radiography; sulphur compounds; Blumlein switches; FXR radiographic facility; LINAC; Lawrence Livermore National Laboratory; flash X-ray radiographic facility; induction; pulsed power system; recirculating SF6 gas reclamation system; Acceleration; Electric breakdown; Heart; Laboratories; Linear particle accelerator; Power system reliability; Pulse power systems; Radiography; Sulfur hexafluoride; Switches;
fLanguage
English