• DocumentCode
    2901032
  • Title

    An improved SF6 system for the FXR induction linac blumlein switches

  • Author

    DeHope, W.J. ; Griffin, K.L. ; Kihara, R. ; Ong, M.M. ; Ross, T.O.

  • Author_Institution
    Lawrence Livermore Nat. Lab., Livermore
  • fYear
    2007
  • fDate
    25-29 June 2007
  • Firstpage
    2361
  • Lastpage
    2363
  • Abstract
    The now-mature FXR (flash X-ray) radiographic facility at Lawrence Livermore National Laboratory will be briefly described with emphasis on its pulsed power system. The heart of each accelerating cell´s pulse-forming Blumlein is its sulfur hexafluoride-based triggered closing switch. FXR´s recent upgrade to a recirculating SF6 gas reclamation system will be described and the resulting accelerator performance and reliability improvements documented. This was accompanied by a detailed switch breakdown study on FXR´s test stand and the recent analysis of the resulting statistics will be shown.
  • Keywords
    X-ray applications; linear accelerators; radiography; sulphur compounds; Blumlein switches; FXR radiographic facility; LINAC; Lawrence Livermore National Laboratory; flash X-ray radiographic facility; induction; pulsed power system; recirculating SF6 gas reclamation system; Acceleration; Electric breakdown; Heart; Laboratories; Linear particle accelerator; Power system reliability; Pulse power systems; Radiography; Sulfur hexafluoride; Switches;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2007. PAC. IEEE
  • Conference_Location
    Albuquerque, NM
  • Print_ISBN
    978-1-4244-0916-7
  • Type

    conf

  • DOI
    10.1109/PAC.2007.4441250
  • Filename
    4441250