DocumentCode
2902282
Title
Key skill study of impregnated cathode unit applied in multiple beam klystron
Author
Shiji, Yu ; Yaogen, Ding ; Zhenbai, Jiang ; Feng, Deng ; Caiying, Wang
Author_Institution
Inst. of Electron., Chinese Acad. of Sci., Beijing, China
fYear
2004
fDate
6-10 Sept. 2004
Firstpage
340
Lastpage
342
Abstract
Multiple beam klystron (MBK) was rapidly developed in recent 20 years because of its unique excellence. Impregnated cathode unit (ICU) with high electronic emission density is one of key technology for manufacture of multi-beam klystron. In this paper, some experiment was made in process of preparing MBK cathode unit. Also several skills were applied to make impregnated cathode unit. The ICUs used in MBK had achieved good result, not only the emission density was satisfied with the demand of device, the problem of electron gun breakdown was overcome also, and the reliability of MBK was improved finally.
Keywords
cathodes; electron guns; klystrons; reliability; MBK reliability; barium evaporation; electron gun breakdown; high electronic emission density; impregnated cathode unit; multiple beam klystron; Anodes; Barium; Cathodes; Electrodes; Electron beams; Electron emission; Klystrons; Microwave devices; System testing; Vacuum systems;
fLanguage
English
Publisher
ieee
Conference_Titel
Vacuum Electron Sources Conference, 2004. Proceedings. IVESC 2004. The 5th International
Print_ISBN
0-7803-8437-7
Type
conf
DOI
10.1109/IVESC.2004.1414267
Filename
1414267