• DocumentCode
    2904074
  • Title

    Accurate RF Voltage Measurements Using a Sampling Voltage Tracker

  • Author

    Souders, T.M. ; Hetrick, P.S.

  • Author_Institution
    National Bureau of Standards
  • fYear
    1988
  • fDate
    7-10 June 1988
  • Firstpage
    270
  • Lastpage
    271
  • Abstract
    The rf voltage measurement capability of an equivalent time sampling system is described. The frequency range investigated is 1 to 100 NHz. Over this range, the measured errors, determined by ac/dc thermal transfer, are within the stated uncertainties presently provided by NBS for thermal converter calibrations. The system offers several advantages over conventional thermal transfer techniques: ac/dc transfers are not required, loading and transmission line problems are reduced, and direct measurement of voltages from 2 V to as low as 10 mV are possible.
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 1988. CPEM 88 Digest. 1988 Conference on
  • Conference_Location
    Ibaraki, Japan
  • Type

    conf

  • DOI
    10.1109/CPEM.1988.671291
  • Filename
    671291