DocumentCode :
2904395
Title :
New equalizer targets for sampled magnetic recording systems
Author :
Fitzpatrick, James ; Wolf, Jack Keil ; Barbosa, Lineu
Author_Institution :
Center for Magnetic Recording Res., California Univ., San Diego, La Jolla, CA, USA
fYear :
1991
fDate :
4-6 Nov 1991
Firstpage :
30
Abstract :
In high density magnetic recording, signals are often equalized to a partial response target of the form (1-D)(1+D)n and then detected by a Viterbi detector using Euclidean distance. The authors use the ideas presented by L.C. Barbosa (1989) to estimate the performance degradation of several different equalizer targets for a tape channel, for a thin film disk channel, and for an ideal Lorentzian channel at a range of densities. The target 1+0.25D-0.75D 2-0.5D3 is shown to outperform the EPR4 target over a large range of densities. It is shown that in the absence of coding there exists little opportunity for performance improvements beyond those found with this target
Keywords :
equalisers; magnetic recording; sampled data systems; signal detection; EPR4 target; Euclidean distance; Viterbi detector; equalizer targets; high density magnetic recording; ideal Lorentzian channel; partial response target; performance degradation; sampled magnetic recording; tape channel; thin film disk channel; AWGN; Additive white noise; Detectors; Equalizers; Euclidean distance; Magnetic recording; Matched filters; Maximum likelihood detection; Maximum likelihood estimation; Viterbi algorithm;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Signals, Systems and Computers, 1991. 1991 Conference Record of the Twenty-Fifth Asilomar Conference on
Conference_Location :
Pacific Grove, CA
ISSN :
1058-6393
Print_ISBN :
0-8186-2470-1
Type :
conf
DOI :
10.1109/ACSSC.1991.186408
Filename :
186408