DocumentCode :
2904652
Title :
The effect of proton and gamma radiation on different types of temperature sensors
Author :
González-Guerrero, Miguel ; Álvarez, María T. ; Jiménez, Juan J. ; Sánchez-Páramo, Jaime ; Guerrero, Héctor
Author_Institution :
Inst. Nac. de Tec. Aeroespacial, Madrid, Spain
fYear :
2009
fDate :
14-18 Sept. 2009
Firstpage :
41
Lastpage :
45
Abstract :
In a study performed to test the effects of proton and gamma radiation on different temperature sensors, Pt RTDs and thermocouples show a negligible sensitivity. On the other hand, IC-based temperature sensors modify significantly their behavior. AD590 sensors exhibit a moderate degradation, depending on the encapsulation. And TMP36 sensors experiment a big degradation amounting up to a change in the readout signal about 20°C for a total ionizing dose of 40 krad.
Keywords :
encapsulation; gamma-ray effects; proton effects; readout electronics; temperature sensors; thermocouples; AD590 sensor; IC-based temperature sensor; RTD; TMP36 sensor experiment; gamma radiation; proton radiation; readout signal; thermocouple; total ionizing dose; Protons; Radiation effects; Sensitivity; Temperature distribution; Temperature measurement; Temperature sensors; Temperature sensors; bipolar linear circuits; radiation effects; total ionizing dose;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Radiation and Its Effects on Components and Systems (RADECS), 2009 European Conference on
Conference_Location :
Bruges
ISSN :
0379-6566
Print_ISBN :
978-1-4577-0492-5
Electronic_ISBN :
0379-6566
Type :
conf
DOI :
10.1109/RADECS.2009.5994550
Filename :