Abstract :
In this paper, several high power lighting networks based on high pressures sodium (HPS) lamps with rated lamp powers of 70, 150 and 250 W have been set up. They have also been tested with different levels of power using dimming for a 220 V power supply. These have been chosen because of they are used in public lighting. Each luminaire consists of sodium lamp with dimmable electronic ballast, which can dim the lamp output smoothly and uniformly. This paper focuses on the harmonic characterization of modern HPS lamps connected to dimmable electronic ballasts. Harmonics under full and reduced power for several HPS lamps have been measured. It presents an investigation on the attenuation effect and a proposal of an index called the equivalent lamp index to characterize this effect on HPS lamps. Also it is concluded that using a combination of HPS lamps can result in a reduction of the current distortion.
Keywords :
harmonic distortion; lamp accessories; lamps; sodium; street lighting; HPS lamps; Na; current distortion reduction; dimmable electronic ballast; equivalent lamp index; harmonic attenuation effect; high power lighting networks; high-pressure sodium lamps; power 150 W; power 250 W; power 70 W; power supply; public lighting; street lighting; voltage 220 V; Attenuation; Electronic ballasts; Harmonic analysis; Harmonic distortion; High intensity discharge lamps; Power system harmonics; Dimming; Harmonic attenuation; Lighting networks; Load combination; Power Quality; Sodium lamps; Street lighting;
Conference_Titel :
Harmonics and Quality of Power (ICHQP), 2010 14th International Conference on
Conference_Location :
Bergamo
Print_ISBN :
978-1-4244-7244-4
Electronic_ISBN :
978-1-4244-7245-1
DOI :
10.1109/ICHQP.2010.5625424