• DocumentCode
    2907832
  • Title

    Phased subarray imaging for low-cost, wideband coherent array imaging

  • Author

    Johnson, Jeremy A. ; Oralkan, O. ; Ergun, Arif Sanli ; Demirci, Utkan ; Karaman, Mustafa ; Khuri-Yakub, Butrus T.

  • Author_Institution
    E. L. Ginzton Labs., Stanford Univ., CA, USA
  • Volume
    2
  • fYear
    2003
  • fDate
    5-8 Oct. 2003
  • Firstpage
    1875
  • Abstract
    The front-end hardware complexity of conventional full phased array (FPA) imaging is proportional to the number of array elements. Phased subarray (PSA) imaging has been proposed as a method of reducing the hardware complexity $and therefore system cost and size - while achieving near-FPA image quality. A new method is presented for designing the subarray-dependent interpolation filters suitable for wideband PSA imaging. The method was tested experimentally using pulse-echo data of a wire target phantom acquired using a 3.2-cm, 128-element capacitive micromachines ultrasonic transducer (CMUT) array with 85% fractional bandwidth at 3 MHz. A specific PSA configuration using seven 32-element subarrays was compared to FPA imaging, representing a 4-fold reduction in front-end hardware complexity and a 43% decrease in frame rate. For targets near the fixed transmit focal distance, the mean 6-dB lateral resolution was identical to that of FPA, the axial resolution improved by 4%, and the SNR decreased by 5 dB. Measurements were repeated for 10 different PSA configurations with subarray sizes ranging from 4 to 60. The lateral and axial resolutions did not vary significantly with subarray size; both the SNR and contrast-to-noise ration (CNR) improved with increased subarray size.
  • Keywords
    antenna phased arrays; filters; image resolution; imaging; phantoms; ultrasonic transducers; 3 MHz; 3.2 cm; FPA imaging; SNR; axial resolution; capacitive micromachines ultrasonic transducer; contrast-to-noise ratio; front-end hardware complexity; full phased array; image quality; lateral resolution; low cost array imaging; phased subarray imaging; pulse-echo data; subarray-dependent interpolation filters; system cost; system size; transmit focal distance; wideband coherent array imaging; wire target phantom; Costs; Filters; Hardware; Image quality; Interpolation; Phased arrays; Testing; Ultrasonic imaging; Ultrasonic transducer arrays; Wideband;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics, 2003 IEEE Symposium on
  • Print_ISBN
    0-7803-7922-5
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2003.1293280
  • Filename
    1293280