Abstract
The Ethernet network is increasingly used for the industrial communications which are strongly time-constrained. This paper presents some test regard the PTP-d software to evaluate the network architectures in term of maximum resolution of synchronization.
Keywords
local area networks; protocols; Ethernet network; clock tracking performances; industrial communications; maximum resolution; network architectures; software-only IEEE 1588 implementation; Clocks; Delay; Instrumentation and measurement; Local area networks; Performance analysis; Performance evaluation; Software standards; Software testing; Synchronization; Timing; IEEE 1588; Precision Timing Protocol; local area network; synchronization; time stamp;