• DocumentCode
    2908501
  • Title

    Analysis of Clock Tracking Performances for a Software-only IEEE 1588 Implementation

  • Author

    Benetazzo, L. ; Narduzzi, C. ; Stellini, M.

  • Author_Institution
    Univ. of Padova, Padova
  • fYear
    2007
  • fDate
    1-3 May 2007
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    The Ethernet network is increasingly used for the industrial communications which are strongly time-constrained. This paper presents some test regard the PTP-d software to evaluate the network architectures in term of maximum resolution of synchronization.
  • Keywords
    local area networks; protocols; Ethernet network; clock tracking performances; industrial communications; maximum resolution; network architectures; software-only IEEE 1588 implementation; Clocks; Delay; Instrumentation and measurement; Local area networks; Performance analysis; Performance evaluation; Software standards; Software testing; Synchronization; Timing; IEEE 1588; Precision Timing Protocol; local area network; synchronization; time stamp;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference Proceedings, 2007. IMTC 2007. IEEE
  • Conference_Location
    Warsaw
  • ISSN
    1091-5281
  • Print_ISBN
    1-4244-0588-2
  • Type

    conf

  • DOI
    10.1109/IMTC.2007.379162
  • Filename
    4258081