    We present the theoretical analysis and experimental performance results of a direct interface for capacitive sensors based on the charge transfer method when parasitic capacitances are included. The interface circuit implements a two-point calibration technique that makes measurement results independent from voltage-and temperature-dependent parameters. The measurement deviation is below 1 % FSR (Full Scale Range) for capacitances from 10 pF to 1 nF.
  • Keywords
    capacitive sensors; charge exchange; capacitive sensors; charge transfer method; direct sensor interface; interface circuit; parasitic capacitances; two-point calibration technique; Calibration; Capacitance measurement; Capacitive sensors; Charge measurement; Charge transfer; Chromium; Circuits; Current measurement; Parasitic capacitance; Voltage; Direct sensor interface; capacitance measurement; capacitive sensor; charge transfer method; microcontroller;