DocumentCode
2911350
Title
Experience with Neil Brown SACM current meters in Lake St. Clair, Canada/USA, 1985
Author
Bull, J.A. ; Valdmanis, J.
Author_Institution
Canada Centre for Inland Waters, Burlington, Ontario, Canada
Volume
3
fYear
1986
fDate
31413
Firstpage
45
Lastpage
51
Abstract
As part of the joint US/Canada Upper Great Lakes Connecting Channel (UGLCC) field measurement study, nine Nell Brown ´Smart´ Acoustic Current Meters (SACM´s) were deployed in Lake St. Clair over the period June to November, 1985. Each of the current meters was moored in a bottom-mounted frame, at a sensing height of one metre, with the acoustic fingers upward. The results of this deployment, and the pre and post-field experience with the SACM ´s are presented here. Since these sensors are relatively new devices and were purchased with specific operations in mind, a short discussion of that rationale is included here. Mention is made of other current measurements systems which were deployed at the same time.
Keywords
Batteries; Current measurement; Lakes; Manufacturing; Pollution measurement; Sampling methods; Sea measurements; Stability; Testing; USA Councils;
fLanguage
English
Publisher
ieee
Conference_Titel
Current Measurement, Proceedings of the 1986 IEEE Third Working Conference on
Type
conf
DOI
10.1109/CCM.1986.1158473
Filename
1158473
Link To Document