    Comparison of radially-symmetric versus oriented channel. Models using channelized hotelling observers for myocardial defect detection in parallel-hole SPECT

  • Author

    Wollenweber, S.D. ; Tsui, B.M.W. ; Lalush, D.S. ; Frey, E.C. ; LaCroix, K.J. ; Gullberg, G.T.

  • Author_Institution
    North Carolina Univ., Chapel Hill, NC, USA
  • Volume
    3
  • fYear
    1998
  • fDate
    1998
  • Firstpage
    2090
  • Abstract
    The objective of this study was to compare defect detection performance found using radially-symmetric (RS) and radially-symmetric broken into oriented channels (OC) models in channelized Hotelling observers with that from a previously reported human observer ROC study. The main goal of the human observer study was to compare detection performance of left-ventricular myocardial perfusion defects using filtered-backprojection (FB) image reconstruction without attenuation compensation to defect detection performance using maximum-likelihood expectation-maximization (ML-EM) image reconstruction with nonuniform attenuation compensation (AC). This was performed for cases of no significant attenuation artifacts (male anatomy, flat diaphragm MF) and significant attenuation reconstruction artifacts (male with raised diaphragm, MR; female with large breasts, F). The areas under the ROC curves (Ax) for the Hotelling observers with both channel models (RS, OC) were calculated and compared to those found in the human observer study. Similar trends with the RC channel model were seen in average observer performance for both human and channelized Hotelling observers in both FB without AC and ML-EM with AC over the three different anatomy types except for the MF anatomy reconstructed with FB. The correlation coefficient for the 6 average observer performances was 0.84. Improved agreement between the human and channelized Hotelling observers was found when using the OC channel model. The correlation coefficient found was 0.94, again with the MF anatomy reconstructed with FB as the most significant difference between the human and channelized Hotelling observer results. Further investigation of the channel models is needed to determine number and alignment of orientations and number and cutoff of frequency bands to improve agreement between human and Hotelling observer results
  • Keywords
    cardiology; image reconstruction; medical image processing; muscle; observers; physiological models; single photon emission computed tomography; channelized Hotelling observers; female with large breasts; flat diaphragm; frequency bands; left-ventricular myocardial perfusion defects; male anatomy; medical diagnostic imaging; myocardial defect detection; nuclear medicine; parallel-hole SPECT; radially-symmetric channel; Anatomy; Attenuation; Biomedical imaging; Breast; Humans; Image reconstruction; Lesions; Liver; Maximum likelihood detection; Myocardium;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
  • Conference_Location
    Toronto, Ont.
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-5021-9
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1998.773944
  • Filename
    773944