• DocumentCode
    2911715
  • Title

    Tracking motor capability of MOVs to maintain design operability

  • Author

    Hussain, B. ; Alsammarae, Aiham

  • Author_Institution
    KCI Eng. Consultants, Downer Grove, IL, USA
  • Volume
    3
  • fYear
    1998
  • fDate
    1998
  • Firstpage
    2133
  • Abstract
    The purpose of this paper is to develop a methodology to measure the motor capability of AC motors used in motor operated valves (MOVs) under a degraded voltage condition. The methodology is based on the measurement of the motor at the motor control center that can readily be performed during surveillance testing or in an outage. Field verification of the methodology is also provided to assure reliability. This approach will help resolve verifying the AC MOV´s design basis capability at torque switch or control switch trip settings. The methodology can be effectively used at the motor control center and predict reliably the left torque capability of the motor to resolve the response to NRC GL 95-05 (periodic verification testing)
  • Keywords
    AC motors; nuclear power stations; valves; AC motors; control switch; degraded voltage condition; design basis capability; motor capability; motor control; motor operated valves; reliability; torque switch; AC motors; Degradation; Motor drives; Performance evaluation; Surveillance; Switches; Testing; Torque control; Valves; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
  • Conference_Location
    Toronto, Ont.
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-5021-9
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1998.773951
  • Filename
    773951