Title :
The RF Voltage Standard Analysis by Parameter Variation
Author_Institution :
Czechoslovak Institute of Metrology
Abstract :
The method of the analysis of the thermistor bolometer of the RF voltage standard covering the frequency range up to 1000 MHz is described. The evaluation of the AC/DC difference of the voltage standard is independent of any other RF quantity measurement and serves the accuracy which meets the requirements of the primary standardization.
Conference_Titel :
Precision Electromagnetic Measurements, 1988. CPEM 88 Digest. 1988 Conference on
Conference_Location :
Ibaraki, Japan
DOI :
10.1109/CPEM.1988.671353